32 Series
The photo of 32M is shown
Features
- It is a non-resettable thermal link that uses a fusible alloy for its thermal element.
- It is compliant with RoHS2.
- Extremely simple construction ensures reliability, and hermetically sealed thermal element reduces deterioration with age.
- It has superior thermal sensitivity.
- It uses an insulating container.
- Please feel free to ask us about cutting, forming, and taping of lead wire.
Lead length | Dimensions (mm) | ||||
---|---|---|---|---|---|
A | B | C | D | E | |
Regular | 6.0±0.5 | 39±3 | 2.0±0.1 | 2.3or below | 0.53±0.02 |
Long | 6.0±0.5 | 69±3 | 2.0±0.1 | 2.3or below | 0.53±0.02 |
Specification
Type No. | Rated functioning temperature Tf (℃) | Functioning temperature (℃) |
Holding temperature Th (℃) | Maximum use temperature (℃) | Maximum temperature limitTm (℃) | Electrical rating | |
---|---|---|---|---|---|---|---|
Ampere (A) |
Voltage (V) |
||||||
32E | 108 | 104±3 | 92 | 86 | 200 | 1 | AC250 |
88 | 82 | 2 | AC125 | ||||
322 | 115 | 112±3 | 89 | 89 | 200 | 1 | AC250 |
2 | AC125 | ||||||
85 | 78 | 4 | DC50 | ||||
32X | 133 | 129±3 | 119 | 109 | 200 | 1 | AC250 |
115 | 106 | 2 | AC125 | ||||
101 | 94 | 4.5 | DC50 | ||||
32M | 139 | 135±3 | 118 | 118 | 200 | 1 | AC250 |
32J | 145 | 141±3 | 127 | 122 | 200 | 0.8 | AC250 |
120 | 115 | 2 | AC125 |
Safety standard information
Type No. | Safety standard approval | |||||
---|---|---|---|---|---|---|
PSE | UL | C-UL | VDE | CCC | KC | |
32E | JET5267-32001-1004 (AC250V) |
E50082 | E50082 | 40009979 | 2020980205000084 (AC250V) |
SU05029-8003 (AC250V) |
322 | JET5267-32001-1004 (AC250V) |
E50082 | E50082 | 40007524 | 2020980205000084 (AC250V) |
SU05029-8003 (AC250V) |
32X | JET5267-32001-1005 (AC250V) |
E50082 | E50082 | 40009979 | 2020980205000095 (AC250V) |
SU05029-8001 (AC250V) |
32M | JET5267-32001-1005 | E50082 | E50082 | 40009979 | 2020980205000093 | SU05029-8001 |
32J | JET5267-32001-1006 (AC250V) |
E50082 | E50082 | 40009979 | 2020980205000094 (AC250V) |
SU05029-8001 (AC250V) |
- Functioning temperature is measured with silicone oil bath of which temperature is increased at the rate of 1℃/min. Detecting current is 0.1A or less.
- Please feel free to contact us in regard of the details of safety standard approvals.
Application guidance
- ELCUT THERMAL LINKS INSTRUCTION MANUAL
- About Thermal links
- Types and Characteristics of Thermal links
- Performance of Thermal links
- Utilization Technology
- Technology Trends
- Thermal links ( Caution)
- Thermal links ( Caution to be observed when designing for use of thermal links)
- Thermal links ( Caution to be observed when installing thermal links)
- Thermal links (Other caution)