H□F Series
Features
- It is a non-resettable thermal link that uses a fusible alloy for its thermal element.
- It is compliant with RoHS2.
- Extremely simple construction ensures reliability, and hermetically sealed thermal element reduces deterioration with age.
- It has superior thermal sensitivity.
- It uses an insulating container.
- Please feel free to ask us about cutting, forming, and taping of lead wire.
Lead length | Dimensions (mm) | ||||
---|---|---|---|---|---|
A | B | C | D | E | |
Regular | 42±3 | 5.9±0.1 | 6.7±0.1 | 2.5±0.1 | 0.55±0.05 |
Long | 74±3 | 5.9±0.1 | 6.7±0.1 | 2.5±0.1 | 0.55±0.05 |
Specification
Type No. | Rated functioning temperature Tf (℃) | Functioning temperature (℃) |
Holding temperature Th (℃) | Maximum use temperature (℃) | Maximum temperature limitTm (℃) | Electrical rating | |
---|---|---|---|---|---|---|---|
Ampere (A) |
Voltage (V) |
||||||
H4F | 127 | 123±2 | 100 | 90 | 200 | 3.0 | AC250 |
95 | 90 | 3.5 | AC125 | ||||
95 | 80 | 4.0 | DC50 | ||||
H6F | 139 | 134±2 | 110 | 90 | 200 | 2.5 | AC250 |
105 | 90 | 3.5 | AC125 | ||||
100 | 80 | 4.0 | DC50 | ||||
H7F | 145 | 140±2 | 115 | 115 | 200 | 2.0 | AC250 |
110 | 110 | 3.5 | AC125 | ||||
105 | 80 | 4.0 | DC50 |
Safety standard information
Type No. | Safety standard approval | |||||
---|---|---|---|---|---|---|
PSE | UL | C-UL | VDE | CCC | KC | |
H4F | JET5823-32001-1004 (AC250V) |
E73591 | E73591 | 40009806 | 2020980205000123 (AC250V) |
SU05028-10004 (AC250V) |
H6F | JET5823-32001-1004 (AC250V) |
E73591 | E73591 | 40009806 | 2020980205000124 (AC250V) |
SU05028-10004 (AC250V) |
H7F | JET5823-32001-1005 (AC250V) |
E73591 | E73591 | 40009806 | 2020980205000121 (AC250V) |
SU05028-10004 (AC250V) |
- Functioning temperature is measured with silicone oil bath of which temperature is increased at the rate of 1℃/min.
Detecting current is 0.1A or less. - Please feel free to contact us in regard of the details of safety standard approvals.