Thermal-links

Thermal-links

L□F Series

L□F Series

Features

  • It is a non-resettable thermal link that uses a fusible alloy for its thermal element.
  • It is compliant with RoHS2.
  • Extremely simple construction ensures reliability, and hermetically sealed thermal element reduces deterioration with age.
  • It has superior thermal sensitivity.
  • It uses an insulating container.
  • Please feel free to ask us about cutting, forming, and taping of lead wire

Lead length Dimensions (mm)
A B C D E
Regular L□F-C 11.5±0.7 38±3 3.3±0.2 3.6 or below 1.0±0.05
Long L□F 11.5±0.7 68±3 3.3±0.2 3.6 or below 1.0±0.05

Specification

Type No. Rated functioning temperature Tf (℃) Functioning temperature
(℃)
Holding temperature Th (℃) Maximum use temperature (℃) Maximum temperature limitTm (℃) Electrical rating
Ampere
(A)
Voltage
(V)
L4F 127 123±2 105 90 200 5.0 AC250
100 90 7.0 AC125

Safety standard information

Type No. Safety standard approval
PSE UL C-UL VDE CCC KC
L4F JET5823-32001-1004
(AC250V)
E73591 E73591 40016342 2020980205000115
(AC250V)
SU05028-10004
(AC250V)
  • Functioning temperature is measured with silicone oil bath of which temperature is increased at the rate of 1℃/min.
    Detecting current is 0.1A or less.
  • Please feel free to contact us in regard of the details of safety standard approvals.
pagetop
loading