Thermal-links

Thermal-links

N□X Series

N□X Series

Features

  • It is a non-resettable thermal link that uses a fusible alloy for its thermal element.
  • It is compliant with RoHS2.
  • Extremely simple construction ensures reliability, and hermetically sealed thermal element reduces deterioration with age.
  • It has superior thermal sensitivity.
  • It uses an insulating container.
  • Please feel free to ask us about cutting, forming, and taping of lead wire.
  • Soldering heatproof is improved, and it is the best for the flow soldering.

Lead length Dimensions (mm)
A B C D E
Regular 40±3 4.1±0.1 5.2±0.1 2.0±0.1 0.53±0.05
Long 72±3 4.1±0.1 5.2±0.1 2.0±0.1 0.53±0.05

Specification

Type No. Rated functioning temperature Tf (℃) Functioning temperature
(℃)
Holding temperature Th (℃) Maximum use temperature (℃) Maximum temperature limitTm (℃) Electrical rating
Ampere
(A)
Voltage
(V)
N5X 136 131±2 100 90 200 1.0 AC250
95 90 2.5 AC125
86 80 3.0 DC50
N6X 139 134±2 110 90 200 1.0 AC250
102 90 2.5 AC125
90 80 3.0 DC50
N7X 145 140±2 125 115 200 1.0 AC250
107 102 2.5 AC125
99 80 3.0 DC50

Safety standard information

Type No. Safety standard approval
PSE UL C-UL VDE CCC KC
N5X JET5823-32001-1004
(AC250V)
E73591 E73591 40009789 2020980205000127
(AC250V)
SU05028-10004 (AC250V)
N6X JET5823-32001-1004
(AC250V)
E73591 E73591 40009789 2020980205000127
(AC250V)
SU05028-10004 (AC250V)
N7X JET5823-32001-1005
(AC250V)
E73591 E73591 40009789 2020980205000127
(AC250V)
SU05028-10004 (AC250V)
  • Functioning temperature is measured with silicone oil bath of which temperature is increased at the rate of 1℃/min.
    Detecting current is 0.1A or less.
  • Please feel free to contact us in regard of the details of safety standard approvals.