Thermal-links

Thermal-links

NC Series

NC Series

Features

  • It is a non-resettable thermal link that uses a fusible alloy for its thermal element.
  • The container can be fixed by screwing.
  • To use tin plated iron wire improves soldering heat resistance. It suitable for flow soldering.
  • It is compliant with RoHS2.
  • Extremely simple construction ensures reliability, and hermetically sealed thermal element reduces deterioration with age.
  • It has superior thermal sensitivity.
  • It uses an insulating container.
  • Please feel free to ask us about cutting, forming, and taping of lead wire.

Lead length Dimensions (mm)
A B C D E F G
Regular 47±3 11.0±0.5 6.7±0.5 2.5±0.3 3.2±0.3 4.5±0.2 0.58±0.05

Specification

Type No. Rated functioning temperature Tf (℃) Functioning temperature
(℃)
Holding temperature Th (℃) Maximum use temperature (℃) Maximum temperature limitTm (℃) Electrical rating
Ampere
(A)
Voltage
(V)
NC2 115 111±3 92 77 200 2 AC250
74 58 3.5 AC125
66 49 4 DC50
NCX 133 129±3 110 95 200 2 AC250
91 77 3.5 AC125
83 68 4 DC50

Safety standard information

Type No. Safety standard approval
PSE UL C-UL VDE CCC KC
NC2 JET5267-32001-1004
(AC250V)
E50082 E50082 40020225 2020980205000083
(AC250V)
SU05029-9007
(AC250V)
NCX JET5267-32001-1005
(AC250V)
E50082 E50082 40020225 2020980205000083
(AC250V)
SU05029-9005
(AC250V)
  • Functioning temperature is measured with silicone oil bath of which temperature is increased at the rate of 1℃/min. Detecting current is 0.1A or less.
  • Please feel free to contact us in regard of the details of safety standard approvals.
pagetop