Thermal-links

Thermal-links

S Series

S Series

Features

  • It is a non-resettable thermal link that uses a fusible alloy for its thermal element.
  • It is compliant with RoHS2.
  • Extremely simple construction ensures reliability, and hermetically sealed thermal element reduces deterioration with age.
  • It has superior thermal sensitivity.
  • It uses an insulating container.
  • Please feel free to ask us about cutting, forming, and taping of lead wire.

Lead length Dimensions (mm)
A B C D E
Regular 55±3 4.0±0.5 5.2±0.5 2.2±0.3 0.53±0.02
Long 70±3 4.0±0.5 5.2±0.5 2.2±0.3 0.53±0.02

Specification

Type No. Rated functioning temperature Tf (℃) Functioning temperature
(℃)
Holding temperature Th (℃) Maximum use temperature (℃) Maximum temperature limitTm (℃) Electrical rating
Ampere
(A)
Voltage
(V)
SE 108 104±3 92 85 200 1 AC250
89 82 1.5 AC125
S2 115 112±3 89 89 200 1 AC250
1.5 AC125
SX 133 129±3 116 108 200 1 AC250
115 107 1.5 AC125
SJ 145 141±3 123 120 200 0.8 AC250

Safety standard information

Type No. Safety standard approval
PSE UL C-UL VDE CCC KC
SE JET5267-32001-1004
(AC250V)
E50082 E50082 40010816 2020980205000087
(AC250V)
SU05029-9007
(AC250V)
S2 JET5267-32001-1004
(AC250V)
E50082 E50082 40007547 2020980205000087
(AC250V)
SU05029-9007
(AC250V)
SX JET5267-32001-1005
(AC250V)
E50082 E50082 40010816 2020980205000087
(AC250V)
SU05029-9005
(AC250V)
SJ JET5267-32001-1006 E50082 E50082 40010816 2020980205000092 SU05029-9005
  • Functioning temperature is measured with silicone oil bath of which temperature is increased at the rate of 1℃/min. Detecting current is 0.1A or less.
  • Please feel free to contact us in regard of the details of safety standard approvals.