Thermal-links

Thermal-links

T□X Series

T□X Series

Features

  • It is a non-resettable thermal link that uses a fusible alloy for its thermal element.
  • It is compliant with RoHS2.
  • Extremely simple construction ensures reliability, and hermetically sealed thermal element reduces deterioration with age.
  • It has superior thermal sensitivity.
  • It uses an insulating container.
  • Please feel free to ask us about cutting, forming, and taping of lead wire.
  • Soldering heatproof is improved, and it is the best for the flow soldering.

Lead length Dimensions (mm)
A B C D E
Regular T□X 6.3±0.3 38±3 2.0±0.1 2.3or below 0.53±0.05

Specification

Type No. Rated functioning temperature Tf (℃) Functioning temperature
(℃)
Holding temperature Th (℃) Maximum use temperature (℃) Maximum temperature limitTm (℃) Electrical rating
Ampere
(A)
Voltage
(V)
T1X 86 81±2 60 55 200 1.0 AC250
54 49 2.0 AC125
44 39 2.5 DC50
T2X 102 98±3 73 70 200 2.0 AC250
53 48 3.0 AC125
53 48 3.0 DC50
T7X 145 140±2 125 115 200 1.0 AC250
105 100 2.5 AC125
92 80 3.0 DC50

Safety standard information

Type No. Safety standard approval
PSE UL C-UL VDE CCC KC
T1X JET5823-32001-1002
(AC250V)
E73591 E73591 40009915 2020980205000110
(AC250V)
SU05028-10002
(AC250V)
T2X JET5823-32001-1003
(AC250V)
E73591 E73591 40009915 2020980205000109
(AC250V)
SU05028-10001
(AC250V)
T7X JET5823-32001-1005
(AC250V)
E73591 E73591 40009915 2020980205000110
(AC250V)
SU05028-10004
(AC250V)
  • Functioning temperature is measured with silicone oil bath of which temperature is increased at the rate of 1℃/min.
    Detecting current is 0.1A or less.
  • Please feel free to contact us in regard of the details of safety standard approvals.