BZ05 (Caution to be observed when installing)
1. Cautions to be observed in handling BZ05
a) Do not apply tensile stress exceeding the force in Table 1to the lead terminals for installation. The stress exceeding the force may cause damage to BZ05.
Table1 BZ05 Terminal maximum tensile force
Maximum tensile force |
22.2 N |
b) Do not bend or twist lead terminals of BZ05. Do not pull or push the lead terminals at an angle other than the original direction from the body. Pulling or pushing may cause damage.
c) Do not apply excessive force on the body of BZ05. That may cause damage.
d) For fixing BZ05 after connecting, be careful not to apply excessive force which damage, push and pull the body and lead terminal of BZ05.
2. Cautions to be observed in installing BZ05
Be sure to connect BZ05 with screw and its appropriate tightening torque. The recommended torque with M5 screw is 3.0N・m. If the torque exceeds the appropriate tightening torque, that may cause the disconnection and result in the characteristic deterioration. If the torque is small, that may cause the loose screw, the rising of resistance value at connection part, the abnormal heating at current application, and result in malfunction of BZ05. Check the connecting state, such as by measuring the resistance value after connecting. In addition, an appropriate loosening prevention treatment shall be recommended.
Application guidance
- ELCUT THERMAL LINKS INSTRUCTION MANUAL
- ELCUT THERMOPROTECTOR ETR INSTRUCTION MANUAL
- ELCUT THERMOPROTECTOR WITH RESISTOR EC INSTRUCTION MANUAL
- ELCUT THERMOPROTECTOR TR4L INSTRUCTION MANUAL
- ELCUT THERMOPROTECTOR TR6L INSTRUCTION MANUAL
- Thermal links/resistor assemblies (Caution)
- Thermal links/resistor assemblies (Caution to be observed when designing for use of thermal links)
- Thermal links/resistor assemblies (Caution to be observed when installing thermal links)
- Thermal links/resistor assemblies (Other caution)
- Thermoprotector with resistor (Caution to be observed when installing thermal links)
- Thermoprotector with resistor (Caution to be observed when designing for use of thermal links)
- Thermoprotector with resistor (Other caution)
- The Fusing Resistor BZ05 (Caution to be observed when designing)
- BZ05 (Caution to be observed when installing)
- BZ05 (Other caution)
- The Fusing Resistor BZ07 (Caution to be observed when designing)
- BZ07 (Caution to be observed when installing)
- BZ07 (Other caution)
- ELCUT Thermal links/resistor assemblies INSTRUCTION MANUAL
- Thermal links ( Caution)
- Thermal links ( Caution to be observed when designing for use of thermal links)
- Thermal links ( Caution to be observed when installing thermal links)
- Thermal links (Other caution)